Sensoray 2600 Programming Guide 66 Comport Transaction Functions
Returns: Error/status value, as described in section 8.1.1.
Notes: Following a MM reset, S26_ComSetMode() should be called to configure each comport that will be used. A
comport must be configured before opening it or attempting to send data to or receive data from its remote serial
device.
The target comport must be closed when S26_ComSetMode() is called. If the comport is open, the command will
be rejected and the status byte’s COM_REJECTED flag will be set.
Example: // Configure COM1 on MM number 0 for the following operating mode:
// 9600 baud, no parity, 8 data, one stop, no flow control, light LED upon receive.
u32 errstat = S26_ComSetMode( 0,
LOGDEV_COM1,
SIO_BR_9600,
SIO_PHY_RS232 | SIO_PARITY_NONE | SIO_DATA_8 | SIO_STOP_1 | SIO_FLOW_OFF,
SIO_LED_RECEIVE,
1000,
1 );
if ( errstat & GWERRMASK )
printf( "COM1 error detected.\n" );
else if ( errstat & COM_REJECTED )
printf( "Error: cannot set mode while COM1 is open.\n" );
else
printf( "Successfully configured COM1.\n" );
8.2.2 S26_ComSetBreakChar()
Function: Specifies the Break character for a comport.
Prototype: u32 S26_ComSetBreakChar( u32 hbd, u8 dev, u8 BreakChar, u32 msec, u32 retries );
Returns: Error/status value, as described in section 8.1.1.
Notes: Following a MM reset, S26_ComSetBreakChar() may be called for each comport to specify the port’s break
character. The break character will be automatically inserted into the comport’s receive buffer in the event a break
Parameter Type Description
hbd u32
MM handle.
dev u8
Logical device identifier for the target comport. Specify a value from 1 to 4 to
address comport 1 to 4, respectively.
BreakChar u8
Specifies the character that is to be inserted into the receive buffer upon detection of
an incoming break condition. The default break character is 0x00 upon power-up or
reset of the MM.
msec u32
Maximum time, in milliseconds, to wait for the MM to respond.
retries u32
Maximum number of transaction retry attempts.
The leds byte is shown to the right.
When set to logic one, each bit will cause the comport’s status
LED to light for approximately 100 milliseconds in response
to the associated event.
Any combination of these bits may be specified. For
example, the XMT and RCV bits may both be set, in which case
the LED will light when characters are sent or received at the
comport.
After a module reset, the RCV flag is set and all other flags are
reset to zero.
XMT causes the LED to light when a character is transmitted.
RCV causes the LED to light when a character is received.
ERR causes the LED to light when a receiver break condition
is detected or when an error (framing, overrun or parity) is
detected.
7
0
6
0
5 4
0
3
XMT
2 1 0
RCV
ERR
00